SCG-W2000: Chemiluminescence Imaging System
SCG-W2000: Chemiluminescence Imaging System
Couldn't load pickup availability
Share


Product Introduction
SCG-W2000 is a device that uses chemiluminescence technology for imaging. It is equipped with a high-sensitivity-cooled camera with a resolution of 20 million pixels. It enables fast, accurate, and high-throughput detection and imaging of samples without the need for additional light sources. It finds extensive applications in life sciences, pharmaceuticals, environmental protection, and more.
Product Features
1.Original AI algorithm, capable of quickly calculating the optimal exposure time;
2.Deep cooling, high sensitivity, high-resolution camera, capable of detecting weak signals, greatly reducing image noise;
3.Standard analysis software, capable of automatically identifying and analyzing lanes;
4.10.4-inch touchscreen computer, also compatible with external computers, one-button control switch;
5.Interface available in Chinese/English, simple and intuitive operation.
Product Parameters
Cat.No. | SCG-W2000 |
Dimensions | 400mm*371mm*700mm |
Camera | Deep-cooled high-sensitivity camera, integrated with an efficient cooling module and anti-fogging structure, ensures that the sensor surface does not fog at low temperatures. This unique technology greatly reduces image noise and ensures the acquisition of high-quality images. The temperature of the camera sensor can be controlled through software to maximize the photoelectric conversion quantum efficiency with minimal video or image noise. It supports software-triggered operation mode, allowing for single or multiple image capture with a single trigger. It also supports long exposure mode, with a maximum duration of up to 1 hour. |
Resolution | 5440 x 3648, 20 million pixels |
Pixel Size | 2.4μm x 2.4μm |
Imaging Area | 230mm x 154mm |
Cooling Temperature | Relative ambient temperature:-40°C |
Light Source | 2 sets of LED white light sources, distributed on the left and right sides of the dark box |
Industrial Computer | 10.4-inch, 1024 x 768, with Windows operating system |
External Interfaces | 2 x USB 3.0 ports |
Voltage |
100V-240V |
Power | 100W |
Net | 25Kg |
Notes:1.Do not touch or scratch the internal lenses of the dark box with hands or sharp objects.
2. After placing the experimental samples, make sure to close the cover of the instrument to prevent external light from affecting the experimental results.
3. During imaging experiments, avoid shaking the experimental table or the instrument to maintain image quality.
4. Pay attention to electrical safety. Do not pull or move the power cord during the experiment.
5. After completing the experiment, clean the samples and any residual materials inside the dark box thoroughly.
Product Introduction
SCG-W2000 is a device that uses chemiluminescence technology for imaging. It is equipped with a high-sensitivity-cooled camera with a resolution of 20 million pixels. It enables fast, accurate, and high-throughput detection and imaging of samples without the need for additional light sources. It finds extensive applications in life sciences, pharmaceuticals, environmental protection, and more.
Product Features
1.Original AI algorithm, capable of quickly calculating the optimal exposure time;
2.Deep cooling, high sensitivity, high-resolution camera, capable of detecting weak signals, greatly reducing image noise;
3.Standard analysis software, capable of automatically identifying and analyzing lanes;
4.10.4-inch touchscreen computer, also compatible with external computers, one-button control switch;
5.Interface available in Chinese/English, simple and intuitive operation.
Product Parameters
Cat.No. | SCG-W2000 |
Dimensions | 400mm*371mm*700mm |
Camera | Deep-cooled high-sensitivity camera, integrated with an efficient cooling module and anti-fogging structure, ensures that the sensor surface does not fog at low temperatures. This unique technology greatly reduces image noise and ensures the acquisition of high-quality images. The temperature of the camera sensor can be controlled through software to maximize the photoelectric conversion quantum efficiency with minimal video or image noise. It supports software-triggered operation mode, allowing for single or multiple image capture with a single trigger. It also supports long exposure mode, with a maximum duration of up to 1 hour. |
Resolution | 5440 x 3648, 20 million pixels |
Pixel Size | 2.4μm x 2.4μm |
Imaging Area | 230mm x 154mm |
Cooling Temperature | Relative ambient temperature:-40°C |
Light Source | 2 sets of LED white light sources, distributed on the left and right sides of the dark box |
Industrial Computer | 10.4-inch, 1024 x 768, with Windows operating system |
External Interfaces | 2 x USB 3.0 ports |
Voltage |
100V-240V |
Power | 100W |
Net | 25Kg |
Notes:1.Do not touch or scratch the internal lenses of the dark box with hands or sharp objects.
2. After placing the experimental samples, make sure to close the cover of the instrument to prevent external light from affecting the experimental results.
3. During imaging experiments, avoid shaking the experimental table or the instrument to maintain image quality.
4. Pay attention to electrical safety. Do not pull or move the power cord during the experiment.
5. After completing the experiment, clean the samples and any residual materials inside the dark box thoroughly.
This is an answer
When can I expect my order to ship? Most orders are filled and shipped within 2-3 business days from the time they are received. Our standard shipping usually take 2-5 days. In case of a back order, we will immediately notify the customer by email. We also provide express shippping for time-sensitive deliveries. Email info@genelabx.com if you have any requirements.This is an answer
When can I expect my order to ship? Most orders are filled and shipped within 2-3 business days from the time they are received. Our standard shipping usually take 2-5 days. In case of a back order, we will immediately notify the customer by email. We also provide express shippping for time-sensitive deliveries. Email info@genelabx.com if you have any requirements.