SWE-FP: Tissue Homogenizer Low Temperature (-50℃, Freezing Table)
SWE-FP: Tissue Homogenizer Low Temperature (-50℃, Freezing Table)
Couldn't load pickup availability
Share


Product Introduction
SWE-FP is a newly upgraded low-temperature homogenizer, which can reach a temperature as low as -50℃ in the chamber and also equipped with a freezing chamber.Adopt high-speed reciprocating motion of the vertical shaking system, the frozen sample in the grinding tube collides with the grinding bead, and the resulting grinding shear force and impact force completely break down the tissue. Up to 192 samples can be processed simultaneously in one minute, making it a dedicated device that meets the requirements of rapid processing of multi-sample.
Product Features
1. Slider drive, no wear shaft, noise stability and durability;
2. Equiped with low temperature freezing chamber. It can meet the needs of sample storage, electrophoresis, membrane transfer and other low-temperature experiments
3. Imported compressor,lowest cooling temperature of -50℃,low temperature grinding throughout the process,reducing degradation of proteins and RNA.
4. Up to 192 samples can be processed simultaneously in 1 minute (24 samples can be processed with standard),efficiently and effectively completing sample grinding with high throughput.
5. Multiple adapters to choose.
Technical Parameters
1. Dimensions:Length 650mm,Width 420mm,Height 430mm
2. Weight:54 kg
3. Screen size:5 inches
4. Temperature:-50℃
5. Temperature control precision:±1℃
6. Working time:Runtime0-9999s,pausetime0-999s,andruntimes1-99times
Parameters Comparison
Cat. No. |
SWE-FP |
Operating mode |
The vertical shaking system moves back and forth at high speed. |
Temperature |
-50℃ |
Temperature control precision |
±1℃ |
Standard spec. |
24*2 mL |
Maximum sample volume |
192 pcs |
Adapter specification |
24x0.5mL.24x2mL.48x2mL. |
Freezing chamber |
YES |
Adapter fixing method |
Nut |
Working time |
0-99min99s |
Dimensions |
650*420*430mm |
Screen size |
5 inches |
Emergency stop button |
YES |
Electromagnetic safety lock |
Screen click control with automatic power-off unlocking. the cover cannot be opened during operation until the grinding program ends, fully protected. |
Maximum feeding size |
No requirements, adjustable according to the adapter. |
Weight |
54kg |
Power parameters |
200-240VAC,50-60 Hz,500 W |
Cooling method |
Compressor cooling |
Transport screws |
Yes (2 at the bottom) |
Advantages |
Lower cooling temperature can reach -50℃. low temperature freezing chamber, |
Equipment List
No. |
Product Name |
Model/Specification |
Quantity |
Remarks |
1 |
Tissue Homogenizer |
SWE-FP |
1 |
|
2 |
Standard Hollow Adapter |
2mL*24 |
1 |
Can process 24 samples at once |
3 |
Beads Pen |
SYM-04Z |
1 |
Suitable for 2mL grinding tubes, zirconia beads 4mm |
4 |
Beads Pen |
SYM-04B |
1 |
Suitable for 2mL grinding tubes, steel beads 4mm |
5 |
Beads Pen |
SYM-03B |
1 |
Suitable for 2mL grinding tubes, steel beads 3mm |
6 |
2mL Centrifuge Tube |
1 |
Tube wall is thickened, material strength is higher, and there is no RNA enzyme. |
Protein Extraction
Product Name |
Grinding Beads |
Frequency |
Grinding Time |
Pause Time |
Cycle times |
Recommended Extraction Solution |
Plant Stems, Leaves |
Stainless Steel Beads 3mm*3, 4mm*1 |
60Hz |
60s |
15s |
3 |
Protein Extraction Solution |
Heart, Liver, Spleen, Lungs, Kidneys, Brain of Mice and Rats |
Stainless Steel Beads 3mm*2, 4mm*1 |
60Hz |
30s |
15s |
2 |
Protein Extraction Solution |
Stomach, Intestines, Muscles, Fat, Pancreas of Mice and Rats |
Stainless Steel Beads 3mm*2, 4mm*1 |
60Hz |
45s |
15s |
2 |
Protein Extraction Solution |
Skin, Ears, Tail, Blood Vessels of Mice and Rats |
Stainless Steel Beads 3mm*3, 4mm*2 |
70Hz |
60s |
20s |
3 |
Protein Extraction Solution |
Cartilage, Hair, Hard Bones of Mice and Rats |
Stainless Steel Beads 3mm*4, 4mm*2 |
70Hz |
90s |
20s |
3 |
Protein Extraction Solution |
(This condition is for reference only, and can be adjusted at any time during the experiment according to the grinding effect.)
RNA Extraction
Product Name |
Grinding Beads |
Frequency |
Grinding Time |
Pause Time |
Cycle times |
Recommended Extraction Solution |
Plant Stems, Leaves |
Zirconia Beads 3mm*3, 4mm*1 |
60Hz |
60s |
15s |
3 |
RNA Extraction Solution |
Heart, Liver, Spleen, Lungs, Kidneys, Brain of Mice and Rats |
Zirconia Beads Beads 3mm*2, 4mm*1 |
60Hz |
30s |
15s |
2 |
RNA Extraction Solution |
Stomach, Intestines, Muscles, Fat, Pancreas of Mice and Rats |
Zirconia Beads Beads 3mm*3, 4mm*2 |
60Hz |
45s |
15s |
2 |
RNA Extraction Solution |
Skin, Ears, Tail, Blood Vessels of Mice and Rats |
Zirconia Beads Beads 3mm*4, 4mm*2 |
70Hz |
60s |
20s |
3 |
RNA Extraction Solution |
Cartilage, Hair, Hard Bones of Mice and Rats |
Zirconia Beads Beads 3mm*3, 4mm*4 |
70Hz |
90s |
20s |
3 |
RNA Extraction Solution |
(This condition is for reference only, and can be adjusted at any time during the experiment according to the grinding effect.)
For RNA extraction, the grinding time is extended compared with that of protein extraction, and RNA extraction solution is added to the grinding, the specific grinding time depends on the amount and type of tissue to be ground. Samples difficult to break can be repeated grinding 2-3 times, the specific situation can be adjusted appropriately according to the experiment.
Strong and Tough Tissue Grinding
For samples that are difficult to grind (e.g. cartilage, hair, etc.), we recommend using a 2mL grinding tube. Cut the sample into 1-2mm pieces, add the appropriate number of grinding beads, cover the tube tightly and freeze in liquid nitrogen for 2-3min without extracting solution, dry grind for 60 seconds at 70Hz, then add extracting solution to the tube and repeat the grinding once. If the grinding result is not satisfactory, the tube can be frozen again and the above experimental steps can be repeated.
Bone Tissue Grinding
For bone tissue, use the special steel grinding jar and adapter. The bone tissue is first frozen in liquid nitrogen for 5-10min, then put into the grinding jar, add the steel beads, and grind for 180 seconds at 70Hz (set cycle grinding). After grinding, take out the finished tissue, put it into a 2mL grinding tube, add the extraction solution, two 3mm grinding beads and homogenize for 60 seconds.
Product Introduction
SWE-FP is a newly upgraded low-temperature homogenizer, which can reach a temperature as low as -50℃ in the chamber and also equipped with a freezing chamber.Adopt high-speed reciprocating motion of the vertical shaking system, the frozen sample in the grinding tube collides with the grinding bead, and the resulting grinding shear force and impact force completely break down the tissue. Up to 192 samples can be processed simultaneously in one minute, making it a dedicated device that meets the requirements of rapid processing of multi-sample.
Product Features
1. Slider drive, no wear shaft, noise stability and durability;
2. Equiped with low temperature freezing chamber. It can meet the needs of sample storage, electrophoresis, membrane transfer and other low-temperature experiments
3. Imported compressor,lowest cooling temperature of -50℃,low temperature grinding throughout the process,reducing degradation of proteins and RNA.
4. Up to 192 samples can be processed simultaneously in 1 minute (24 samples can be processed with standard),efficiently and effectively completing sample grinding with high throughput.
5. Multiple adapters to choose.
Technical Parameters
1. Dimensions:Length 650mm,Width 420mm,Height 430mm
2. Weight:54 kg
3. Screen size:5 inches
4. Temperature:-50℃
5. Temperature control precision:±1℃
6. Working time:Runtime0-9999s,pausetime0-999s,andruntimes1-99times
Parameters Comparison
Cat. No. |
SWE-FP |
Operating mode |
The vertical shaking system moves back and forth at high speed. |
Temperature |
-50℃ |
Temperature control precision |
±1℃ |
Standard spec. |
24*2 mL |
Maximum sample volume |
192 pcs |
Adapter specification |
24x0.5mL.24x2mL.48x2mL. |
Freezing chamber |
YES |
Adapter fixing method |
Nut |
Working time |
0-99min99s |
Dimensions |
650*420*430mm |
Screen size |
5 inches |
Emergency stop button |
YES |
Electromagnetic safety lock |
Screen click control with automatic power-off unlocking. the cover cannot be opened during operation until the grinding program ends, fully protected. |
Maximum feeding size |
No requirements, adjustable according to the adapter. |
Weight |
54kg |
Power parameters |
200-240VAC,50-60 Hz,500 W |
Cooling method |
Compressor cooling |
Transport screws |
Yes (2 at the bottom) |
Advantages |
Lower cooling temperature can reach -50℃. low temperature freezing chamber, |
Equipment List
No. |
Product Name |
Model/Specification |
Quantity |
Remarks |
1 |
Tissue Homogenizer |
SWE-FP |
1 |
|
2 |
Standard Hollow Adapter |
2mL*24 |
1 |
Can process 24 samples at once |
3 |
Beads Pen |
SYM-04Z |
1 |
Suitable for 2mL grinding tubes, zirconia beads 4mm |
4 |
Beads Pen |
SYM-04B |
1 |
Suitable for 2mL grinding tubes, steel beads 4mm |
5 |
Beads Pen |
SYM-03B |
1 |
Suitable for 2mL grinding tubes, steel beads 3mm |
6 |
2mL Centrifuge Tube |
1 |
Tube wall is thickened, material strength is higher, and there is no RNA enzyme. |
Protein Extraction
Product Name |
Grinding Beads |
Frequency |
Grinding Time |
Pause Time |
Cycle times |
Recommended Extraction Solution |
Plant Stems, Leaves |
Stainless Steel Beads 3mm*3, 4mm*1 |
60Hz |
60s |
15s |
3 |
Protein Extraction Solution |
Heart, Liver, Spleen, Lungs, Kidneys, Brain of Mice and Rats |
Stainless Steel Beads 3mm*2, 4mm*1 |
60Hz |
30s |
15s |
2 |
Protein Extraction Solution |
Stomach, Intestines, Muscles, Fat, Pancreas of Mice and Rats |
Stainless Steel Beads 3mm*2, 4mm*1 |
60Hz |
45s |
15s |
2 |
Protein Extraction Solution |
Skin, Ears, Tail, Blood Vessels of Mice and Rats |
Stainless Steel Beads 3mm*3, 4mm*2 |
70Hz |
60s |
20s |
3 |
Protein Extraction Solution |
Cartilage, Hair, Hard Bones of Mice and Rats |
Stainless Steel Beads 3mm*4, 4mm*2 |
70Hz |
90s |
20s |
3 |
Protein Extraction Solution |
(This condition is for reference only, and can be adjusted at any time during the experiment according to the grinding effect.)
RNA Extraction
Product Name |
Grinding Beads |
Frequency |
Grinding Time |
Pause Time |
Cycle times |
Recommended Extraction Solution |
Plant Stems, Leaves |
Zirconia Beads 3mm*3, 4mm*1 |
60Hz |
60s |
15s |
3 |
RNA Extraction Solution |
Heart, Liver, Spleen, Lungs, Kidneys, Brain of Mice and Rats |
Zirconia Beads Beads 3mm*2, 4mm*1 |
60Hz |
30s |
15s |
2 |
RNA Extraction Solution |
Stomach, Intestines, Muscles, Fat, Pancreas of Mice and Rats |
Zirconia Beads Beads 3mm*3, 4mm*2 |
60Hz |
45s |
15s |
2 |
RNA Extraction Solution |
Skin, Ears, Tail, Blood Vessels of Mice and Rats |
Zirconia Beads Beads 3mm*4, 4mm*2 |
70Hz |
60s |
20s |
3 |
RNA Extraction Solution |
Cartilage, Hair, Hard Bones of Mice and Rats |
Zirconia Beads Beads 3mm*3, 4mm*4 |
70Hz |
90s |
20s |
3 |
RNA Extraction Solution |
(This condition is for reference only, and can be adjusted at any time during the experiment according to the grinding effect.)
For RNA extraction, the grinding time is extended compared with that of protein extraction, and RNA extraction solution is added to the grinding, the specific grinding time depends on the amount and type of tissue to be ground. Samples difficult to break can be repeated grinding 2-3 times, the specific situation can be adjusted appropriately according to the experiment.
Strong and Tough Tissue Grinding
For samples that are difficult to grind (e.g. cartilage, hair, etc.), we recommend using a 2mL grinding tube. Cut the sample into 1-2mm pieces, add the appropriate number of grinding beads, cover the tube tightly and freeze in liquid nitrogen for 2-3min without extracting solution, dry grind for 60 seconds at 70Hz, then add extracting solution to the tube and repeat the grinding once. If the grinding result is not satisfactory, the tube can be frozen again and the above experimental steps can be repeated.
Bone Tissue Grinding
For bone tissue, use the special steel grinding jar and adapter. The bone tissue is first frozen in liquid nitrogen for 5-10min, then put into the grinding jar, add the steel beads, and grind for 180 seconds at 70Hz (set cycle grinding). After grinding, take out the finished tissue, put it into a 2mL grinding tube, add the extraction solution, two 3mm grinding beads and homogenize for 60 seconds.
This is an answer
When can I expect my order to ship? Most orders are filled and shipped within 2-3 business days from the time they are received. Our standard shipping usually take 2-5 days. In case of a back order, we will immediately notify the customer by email. We also provide express shippping for time-sensitive deliveries. Email info@genelabx.com if you have any requirements.This is an answer
When can I expect my order to ship? Most orders are filled and shipped within 2-3 business days from the time they are received. Our standard shipping usually take 2-5 days. In case of a back order, we will immediately notify the customer by email. We also provide express shippping for time-sensitive deliveries. Email info@genelabx.com if you have any requirements.